Power Monitoring Communication Module TTL for AC Voltage Current Power Frequency with CT(100A COil CT )

٨٫٩٥٠ د.ب.‏
والشحن مجاناً

Power Monitoring Communication Module TTL for AC Voltage Current Power Frequency with CT(100A COil CT )

  • العلامة التجارية: Unbranded

Power Monitoring Communication Module TTL for AC Voltage Current Power Frequency with CT(100A COil CT )

  • العلامة التجارية: Unbranded
سعر البيع القطاعي المقترح: ١٠٫٩٥٠ د.ب.‏
السعر: ٨٫٩٥٠ د.ب.‏
أنت توفر: ٢٫٠٠٠ د.ب.‏ (18%)
البائع:
٨٫٩٥٠ د.ب.‏
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

Feature:1. This AC parameter communication module is mainly used to measure AC voltage, current, active power, frequency, power factor and active energy.2. The module has no display function and the data is read through the TTL interface.3. Support for Modbus-RTU standard protocol, including host computer software.4. Comes with TTL to USB data cable and external CT.5. The module works for Windows operating systems.Specification:Item Type: Communication ModuleMeasurement Range: AC 80-260VResolution: 0.1 VAccuracy:0.5%2. Current:Measurement Range:0-100AResolution: 0.001 AAccuracy: 0.5%3. Active PowerMeasurement Range:0-2.3 KWMin. Measuring Power: 0.4WResolution: 0.1W4. Power FactorMeasurement Range: 0.00-1.00Resolution: 0.01Accuracy:1%5. FrequencyRange:45 Hz-65 HzResolution: 0.1 HzAccuracy: 0.5%6. Active Electrical EnergyMetering Range:0-9999.99 kWhResolution: 1WhAccuracy: 0.5%Communication Protocol:1. Physical layer protocol:Physical layer adopts UART to TTL communication interfaceBaud rate:9600,8 bit data bit,1 bit stop bit, no check2. Application layer protocolThe application layer supports for Modbus-RTU protocol for communication and currently only supports function codes such as 0x03 (read-hold register), 0x04 (read-input register), 0x06 (write single register), 0x41 (calibration), 0x42 (power zero).The 0x41 function code is limited to internal use (the address can only be 0xF8), used for factory calibration and back-to-factory maintenance, add a password of 16 bits after the function code, the password default is 0x3721.The address range of the slave computer is 0x01 ~ 0xF7, and the address 0x00 is used as the broadcast address. The slave computer does not need to reply to the host, and the address 0xF8 is used as the general address. The address can only be used in a single-slave environment and can be used for calibration and other operations.3. Read the results of the measurementThe command format for the host to read the result of the measurement is (8 bytes in total):Slave computer address + 0x04 + register address high byte + register address low byte + register number high byte + register number low byte + CRC check high byte + CRC check low byte.Reply of slave computer to the following command format is divided into two types:Correct reply: Slave computer address + 0x04 + bytes + registers 1 data high byte + registers 1 data low byte +...+ CRC check high byte + CRC check low byte.Wrong reply: Slave computer address + 0x84 + exception code + CRC check high byte + CRC check low byte.The exception code is read as follows (the same below):0x01, illegal function; 0x02, illegal address; 0x03, illegal data; 0x04, slave error.The register layout of the measured results is shown in the following table:v\:* {behavior:url(#default#VML);}o\:* {behavior:url(#default#VML);}x\:* {behavior:url(#default#VML);}.shape {behavior:url(#default#VML);}Register addressDescriptionResolution0x000Voltage value measurement1LSB corresponds to 0.1V0x001Current Measurement Value Low 16 Bits1LSB corresponds to 0.01A0x0002Current Measurement Value High 16 Bits0x0003Power Measurement Value Low 16 Bits1LSB corresponds to 0.1W0x0004Power Measurement Value High 16 Bits0x0005Energy Measurement Value Low 16 Bits1LSB corresponds to 1Wh0x0006Energy Measurement Value High 16 Bits0x0007Frequency Measurement Value1LSB corresponds to 0.1Hz0x0008Power Factor Measurement Value1LSB corresponds to 0.010x0009Alarm State0xFFFF alarm0x0000 no alarm4. Read and modify the slave parametersIt supports reading and modifying the address and power alarm settings of the slave machine5. Zero power6. Calibration7. CRC checkPackage List:1 x Module1 x Data Cable1 x CT1 x User ManualNote:The module TTL interface is a passive interface, it needs external 5V power supply, all 4 ports must be linked at the time of communication, otherwise it can't communicate.
  • هوية Fruugo: 425661443-894088036
  • EAN: 7599075566151

التسليم والرد

يُرسل خلال ٢ أيام

  • STANDARD: مجاناً - التسليم بين الخميس 30 أكتوبر 2025 – الأربعاء 05 نوفمبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Shenzhen Mutalai Technology Co., Ltd.
  • Shenzhen Mutalai Technology Co., Ltd.
  • 71001-187, 7/F, Building D, Gaoke Mansion, No. 2076 Yuanyuan Avenue
  • Nanshan Street
  • Nanshan District
  • Shenzhen
  • CN
  • 518000
  • gbyhynnygt@126.com
  • 18664978705
  • https://detail.1688.com/offer/593788918206.html?spm=a2615.7691456.autotrace-offerGeneral.7.4cc915345wLsDx

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • None
  • Kequ Technology s.r.o.
  • Pražákova 1008/69
  • Štýřice
  • Jihomoravský kraj
  • Brno
  • CZ
  • 63900
  • christopher25106@outlook.com
  • 420608214795
  • https://www.noon.com/uae-en/p-29378/