الوصف
Description: _x000D_
This is a electric monitoring test module which can be used to test power, energy, voltage and current then displayed on a PC or other terminals. It can store data when power off, and store the accumulated energy data before power off. Designed with one key reset button, you can reset energy data by simply pressing one button. The TTL serial port can communicate, read and set parameters with a variety of terminals through a USB adapter. _x000D_
_x000D_
_x000D_
Features: _x000D_
This is a electric monitoring test module which can be used to test power, energy, voltage and current. _x000D_
The connection of this module is divided into 2 parts: voltage, current input connection and serial port communication, and you can use different TTL adapters to make it communicate with various terminals. _x000D_
The test module is design to test high power equipment and you can observe the accumulative process intuitively for the low-power(within 100W)load test. _x000D_
There is a button on module for energy reset, simply press and hold the button for 5 seconds and release, then press the button again to finish energy reset. _x000D_
It displays through PC or other terminals, and you can download the software for PC. For other terminals, it need to be programmed by yourself. _x000D_
_x000D_
_x000D_
Specifications: _x000D_
Working Voltage: 80~260VAC _x000D_
Test Voltage: 80~260VAC _x000D_
Rated Power: 100A/22000W _x000D_
Working Frequency: 45-65Hz _x000D_
Measurement Accuracy: 1.0 _x000D_
Board Size: 7.3 x 3 x 2.3cm / 2.87 x 1.18 x 0.9"_x000D_
_x000D_
_x000D_
_x000D_
Display Format: _x000D_
1. Power Test Range: 0~22kW _x000D_
0 ~ 10kW, the display format is 0.000 ~ 9.999 _x000D_
10 ~ 22kW, the display format is 10.00 ~ 22.00 _x000D_
2. Energy Test Range: 0~9999kWh _x000D_
0 ~ 10kWh, the display format is 0.000 ~ 9.999 _x000D_
10 ~ 100kWh, the display format is 10.00 ~ 99.99 _x000D_
100 ~ 1000kWh, the display format is 100.0 ~ 999.9 _x000D_
1000 ~ 9999kWh and above, the display format is 1000 ~ 9999 _x000D_
3. Voltage Test Range: 80~260VAC _x000D_
Display Format is 110.0 ~ 220.0 _x000D_
4. Current Test Range: 0~100A _x000D_
Display Format is 00.00 ~ 99.99 _x000D_
_x000D_
_x000D_
Function: _x000D_
1. Voltage(V), current(A), average power(kW), energy(kWh) measurement. _x000D_
2. Energy reset by pressing one button. _x000D_
3. Store data when power off(store the accumulated energy data before power off). _x000D_
4. PC display function(display voltage, current, average power, energy). _x000D_
5. Serial port communication function(TTL serial port can communicate, read and set parameters with a variety of terminals through a USB adapter). _x000D_
_x000D_
_x000D_
Display Interface: _x000D_
It displays through PC or other terminals(need to be programmed by yourself), the following are brief description of each parameter display: _x000D_
1. Voltage(V) Display _x000D_
Measure and display the voltage of electric power grid. _x000D_
2. Current(A) Display _x000D_
Measure and display the current of load (device). The current test value is from the beginning of 10mA, and this module is designed to test high power equipment, if you need the current testing accuracy in mA level, it is not be recommended. _x000D_
3. Energy(kWh) Display _x000D_
Measure and display the accumulative power consumption. The minimum unit of the energy metering is 0.001kWh, which means it begins to accumulate from 1Wh. You can observe the accumulative process intuitively for the low-power(within 100W)load test. _x000D_
4. Power(kW) Display _x000D_
Measure and display the load power. The power test value is from the beginning of 0.001kW, which means it begins to test from 1W, and this module is designed to test high power equipment, if you have the requirement of testing power within 1W, it is not recommended. _x000D_
_x000D_
_x000D_
Serial Port Communication _x000D_
This module is design with TTL serial port data communication interface, you can read and set the relevant parameters via serial port. If it need to communicate with a device which has USB or RS232 (such as computer), a TTL adapter is required. In the below table are the communication protocols of this module: _x000D_
Function Head Data1- Data5 Sum _x000D_
Voltage B0 C0 A8 01 01 00 (Computer sends a command to read the voltage value) 1A _x000D_
A0 00 E6 02 00 00 (Meter reply the voltage value is 230.2V) 88 _x000D_
Current B1 C0 A8 01 01 00 (Computer sends a command to read the current value) 1B _x000D_
A1 00 11 20 00 00 (Meter reply the current value is 17.32A) D2 _x000D_
Average Power B2 C0 A8 01 01 00 (Computer sends a command to read the average power value) 1C _x000D_
A2 08 98 00 00 00 (Meter reply the active power value is 2200w) 42 _x000D_
Read Energy B3 C0 A8 01 01 00 (Computer sen
-
هوية Fruugo:
309327338-692365358
-
EAN:
925985367644
معلومات سلامة المنتج
يرجى الاطلاع على معلومات سلامة المنتج الخاصة بهذا المنتج الموضحة أدناه
يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.
تحذيرات السلامة:
Do not let your children touch this product alone to avoid swallowing or other injuries.