Timer Control Relay Switch for Water Pump Control Motor Control Light Strip Delay Trigger Timer Delay Switch AC110-220V Multicolor

٩٫٩٥٠ د.ب.‏
والشحن مجاناً

Timer Control Relay Switch for Water Pump Control Motor Control Light Strip Delay Trigger Timer Delay Switch AC110-220V Multicolor

  • العلامة التجارية: Unbranded

Timer Control Relay Switch for Water Pump Control Motor Control Light Strip Delay Trigger Timer Delay Switch AC110-220V Multicolor

  • العلامة التجارية: Unbranded
السعر: ٩٫٩٥٠ د.ب.‏
البائع:
٩٫٩٥٠ د.ب.‏
والشحن مجاناً

في المخزون

نقبل وسائل الدفع الآتية

الوصف

["DC12V AC220V/85-265V Digital Display for Time Relay Module Timer Cycle Control Relay Module\r\nbrand new and high quality\r\n\r\nFeatures:\r\nTiming range: 0-999ms, 0-999s, 0-999m, 0-999h \r\nPower supply voltage: DC12V, AC85-265V (110V 220V)\r\nStatic power: <0.6W\r\nPower: <2000W(maximum) \r\nWorking current: 10A(maximum) \r\nDimensions: 71x39x25mm/2.8x1.54x0.98inch\r\nColor: Black\r\nQuantity: 1 Pc\r\nNote: 1.for DC and AC wiring are the same, the positive pole corresponds to the live line, and the negative pole corresponds to the neutral line.\r\n 2.Please allow 0-1cm error due to manual measurement. pls make sure you do not mind before you bid.\r\n 3.Due to the difference between different monitors, the picture may not reflect the actual color of the item. Thank you!\r\n\r\nPackage includes:\r\n1 x for Time Delay Relay Module\r\n\r\n\r\n\r\n---------------------------------\r\nProduct use instructions:\r\nThis product has four function keys: increase button, decrease button, set button, confirm button\r\nAfter the user gets the product, first understand the function buttons of the product, which is beneficial to the customer's next use.\r\n\r\nfor Time setting: Short press the setting button, the T1 digital tube will flash. During the flashing period, the timing for time T1 is set by adding or subtracting the button. After setting, press the setting button again, the T2 digital tube will flash, and the button will be added or subtracted during the flashing. Set the timing for time T2. There are two ways to save data after setting. The first can wait for 6s, the digital tube stops flashing, the system automatically saves the setting for time, and the second can press the setting button again to save the data.\r\n\r\nParameter setting: Press and hold the setting button to enter the parameter setting mode. There are three sets of parameters for the user to set P0, P1, P2.\r\nP0: Timed range, P1: Operating mode, P2: Display brightness adjustment. P0, P1, P2 can be switched by short pressing the setting button. Under the corresponding parameters, the corresponding parameters can be set by adding or subtracting by pressing the button.\r\nP0--0 represents a timing range of 0.1 seconds.\r\nP0--1 represents the timing range is seconds.\r\nP0--2 represents the timing range is a fraction.\r\nP0--3 represents the timing range is for time.\r\nP1--0: Relay delay after T1 for time (T1 timing).\r\nP1--1: The relay is released after the delay of T1 for time (T1 timing).\r\nP1--2: After the delay for time T1, the relay is closed (T1 timing), and then the relay is released after T2 for time (T2 timing), and ends.\r\nP1--3: The relay is released after the delay for time T1 (T1 timing), and then the relay is closed after the T2 for time (T2 timing), and ends.\r\nP1--4: After the delay for time T1, the relay is closed (T1 timing), and then the relay is released after T2 for time (T2 timing), and the cycle is repeated.\r\nP1--5: The relay is released after the delay for time T1 (T1 timing), and then the relay is closed after the T2 for time (T2 timing), and the cycle is repeated.\r\nP2--0 to P2--5 are display brightness adjustments that the user can set based on comfort.\r\nP2--OFF: Low power mode, the user sets P2 to OFF mode, the system will automatically turn off the display after 10s, enter the low power mode, press any button to wake up.\r\n\r\nThe confirmation button has two major functions:\r\nFunction 1: After all the parameter settings are completed, press the Enter for key to save the setting data and start working. Pressing the ENTER button again during operation will implement the pause function, the relay will be disconnected, and the button will be restored again.\r\nFunction 2: Trigger function again. After the timer finishes working normally, it needs to work again. Short press the confirmation button to re-time.\r\n\r\nFor example: For example, a customer needs to turn on the machine for 10 seconds, shut down for 20 seconds, and cycle. The setting method is as follows:\r\n T1 sets for time 10, T2 sets for time 20\r\nP0-1 (T1 timing range is seconds)\r\n P1—5 (the timer working mode is to stop and cycle all the for time after working)"]
  • هوية Fruugo: 392256827-839264681
  • EAN: 7916000589793

التسليم والرد

يُرسل خلال 24 ساعة

  • STANDARD: مجاناً - التسليم بين الأربعاء 08 أكتوبر 2025 – الاثنين 13 أكتوبر 2025 - مجاناً

يُشحن من الصين.

نحن نبذل قصارى جهدنا لضمان أن تصلك المنتجات التي تطلبها بالكامل وطبقاً المواصفات التي حددتها. إلا أنه في حال تلقيك طلب غير كامل أو أغراض تختلف عن تلك التي طلبتها أو كان هناك سبب آخر يدعوك لعدم الرضاء عن الطلب، فيمكنك رد الطلب أو أي منتجات يتضمنها الطلب واسترداد ما دفعته من أجل تلك الأغراض بالكامل. عرض سياسة الرد الكاملة

تفاصيل امتثال المنت

يرجى الاطلاع على معلومات الامتثال الخاصة بهذا المنتج الموضحة أدناه.

يتم توفير المعلومات التالية من قبل بائع التجزئة المستقل التابع لجهة خارجية الذي يبيع هذا المنتج.

الجهة المصنعة:
توضح المعلومات التالية تفاصيل الاتصال الخاصة بالجهة المصنعة للمنتج ذي الصلة والذي يُباع على Fruugo.

  • Shenzhen Jianming Technology Co., Ltd.
  • Shenzhen Jianming Technology Co., Ltd.
  • 611, 6th Floor, Longsheng Commercial Building, Dalang Street
  • Shenzhen
  • China
  • 518000
  • eo1dxitoes@163.com
  • +8618818900735

الشخص المسؤول في الاتحاد الأوروبي:
توضح المعلومات التالية معلومات الاتصال الخاصة بالشخص المسؤول في الاتحاد الأوروبي. الشخص المسؤول هو المُشغل الاقتصادي المُعيّن والكائن في الاتحاد الأوروبي والمسؤول عن التزامات الامتثال المتعلقة بالمنتج ذي الصلة الذي يُباع داخل الاتحاد الأوروبي.

  • Yating He
  • E-CrossStu GmbH
  • 69 Mainzer Landstrasse
  • Frankfurt am Main
  • Germany
  • 60329
  • E-crossstu@web.de
  • +4969332967674